TS® 19 Test Sets
Key features
- TS19 telephone test equipment features DataSafe™, Tone or Pulse operation, Talk/Monitor capabilities and last number redial.
- High impedance DataSafeTM operation in monitor mode.
- Tone (DTMF) and pulse operation
- Last number redial
- Polarity indication in talk mode
- product overview
- specifications
- What's in the box
Product overview: TS® 19 Test Sets
The Fluke Networks TS19 Test Set combines all the essential test set features at an affordable price. This test set was specifically designed for in-house telecom technicians. Its high impedance monitor prevents accidental disruption of service from clipping onto a data line while in monitor mode, thus ensuring the integrity of critical data lines. Features such as tone (DTMF) or pulse operation, talk/monitor capabilities, polarity test button and last number redial make this test set the perfect combination of features and price.
Specifications: TS® 19 Test Sets
Electrical Specifications
| Parameter | Specification |
|---|---|
| Loop Limit | 2.4 kΩ max at 48 VDC (nominal 15 mA min loop current) |
| DC Resistance (Talk Mode) | 150 Ω typical at 80 mA current |
| AC Impedance (Monitor Mode) | Low impedance (Ring): 600 Ω @ 1 kHz (typical) High impedance (Hi-Z): 100 kΩ min @ 1 kHz |
| Rotary Dial Output - Pulsing Rate | 10 pps ± 0.5 pps |
| Percent Break | 60% ± 2% |
| Interdigit Interval | 800 ms typical |
| Leakage During Break | > 50 kΩ |
| DTMF Output - Tone Frequency Error | ±1% max |
| DTMF Tone Level (per tone pair) | - dBm max, - dBm min (incomplete values, please verify) |
| High vs Low Tone Difference | 4 dB max |
Physical Specifications
| Parameter | Specification |
|---|---|
| Length | 8.75 in (22.2 cm) |
| Width | 2.375 in (6.03 cm) |
| Height | 3.375 in (8.57 cm) |
| Weight | 10.8 oz (0.307 kg) max |
Environmental Specifications
| Parameter | Specification |
|---|---|
| Operating Temp | -5 °C to [value missing] °C |
| Storage Temp | -40 °C to [value missing] °C |
| Drop Test | 1 meter drop, 4 times |
| Altitude | Up to 3,000 meters (10,000 ft) max |
| Humidity | 10% to 80% RH (non-condensing) |
Regulatory Standards & Compliance
| Type | Standard / Directive |
|---|---|
| EMC | 47 CFR Part 15, Subpart B ICES-003 Issue 3 AS/NZS 3548 EN 55022:98 EN 61326:97 A1:98 Annex C EN 61000-4-2 EN 61000-4-3 |
| Low Voltage Directive | LV Directive 73/23/EEC, EN 61010-1 (1993) |
| Certifications | CAN/CSA-C22.2 No. 60950-1-03 CAN/CSA-C22.2 No. 1010.1-92 CSA-C22.2 No. 1010.1B-97 UL/ANSI 3111-1 |
What's in the box:
- TS19 test set with banana jacks to alligator clips